Vista de pagina 29
18
TACHTROL
plus
can be connected to TACHTROL or TACHPAK using high
quality RJ11 connectors and cables. If longer distances or more durable
connections are required, TACHTROL and TACHTROL
plus
can be connected
with larger gauge cables via TB3 and TB1 respectively. Display connections to
TACHPAK can also be upgraded. Simply run a short RJ11 cable to a terminal
block and continue the run with larger gauge cable. When connecting multiple
displays, ensure sufficient power is available to the base tachometer unit (see
section 6). If it is necessary to run on 12volts dc, the supply should be capable of
g and parametric
electrical information.
3.4. Wiring Connections
Terminal
Block
Pin #
TACHTROL
plus
at least 1.5 amps. Also, limit the total number of remote displays to 3.
See Specifications, Section 6 for detailed wirin
1 +12vdc In
2 Sig +
3 Sig -
TB1
Remote
Display
4 Gnd
Remote Display Use RJ11 type connector. See TB1 for
individual breakout of pins.