Host High Speed Electrical Test Procedure Revision 1.4
9. The result contains EL_21 the sync field length (number of bits) of the first and second packets
on the oscilloscope and should be of 32 bits. Refer to the figure below. Note that the Sync Field
starts from the high-speed idle transitions to a falling edge (due to the first zero).
Figure 11: Host Packet Sync Field