Host High Speed Electrical Test Procedure Revision 1.4
10. On the Host Test menu, select RESUME from the Port Control dropdown menu and enter the
port number. Click Execute once to resume the port. The captured suspend transition should
appear as in the following figure.
Figure 19: Time to First EOP from Start of HS Idle
11. The result consists of the time from the falling edge of D+ to the first SOF issued by the host
(EL_41) as shown in the figure above. This is EL_41.
Note: Repeat the suspend and resume a number of times and verify that the time from the
falling edge of D+ to the first SOF issued by the host never exceeds 3 ms.
12. Repeat steps 4 through 9 for all the remaining ports.